PrecisionΒΆ

Type:float
Range:[1e-09, 1]
Default:1e-05
Appearance:simple

This parameter controls the numerical accuracy of the near field. Decreasing it, will result in more accurate results. This parameter is also used as a termination criterion within the Refinement loop.

Warning

It is not guaranteed that after termination the precision of a quantity of interest as computed by a post-process is directly related to the value of this parameter.