PrecisionFarFieldΒΆ
Type: | float |
---|---|
Range: | [1e-09, 1] |
Default: | -/- |
Appearance: | optional |
Sets the goal precision of the complex-valued far field data. The affect of this parameter is identical to Precision except that it provides a termination criterion within the Refinement loop. The refinement will not stop before the given far field precision is reached.
The parameter can be used in combination with Precision (near field precision). Then the refinement loop terminates when both conditions are fulfilled.
Warning
It is not guaranteed that after termination the precision of a quantity of interest as computed by a post-process is directly related to the value of this parameter.